Digital automatic blood pressure monitor. Table Of Contents. Quick Links. See also: Instruction Manual. Table of Contents. Digital Automatic Blood Pressure Monitor. Previous Page. Next Page. Using the Unit It measures your blood pressure and pulse rate simply and quickly.

Page 4: Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. You should never change the dosage of medication prescribed by your doctor. Use the M3 Intellisense only for yourself. Page 5: Overview 1. Overview Main unit A.

Display B. SET button E. Battery compartment F. Air jack G. AC adapter jack for optional AC adapter 1. Arm cuff Medium cuff: arm circumference cm I.

Air Tube J. Air Plug Page 7: Display 2. If flashing after measurement complete indicates blood pressure out of recommended range R. Pulse display S. Deflation symbol T. Page 8: Preparation 2. Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover. You should replace the batteries with new ones ahead of time. Page Setting The Date And Time Setting the Date and Time Your blood pressure monitor automatically stores up to 42 measurements values in its memory and calculates an average value based on the three most recent measurements taken within 10 minutes of the last reading.

If there are only two readings in memory for that period, the average will be based on two readings. Page 11 Press the SET button to confirm the setting when the desired number appears on the display. The year is set and the month digits flash on the display. Repeat steps 2 and 3 to set the month. The month is set and the day digits flash on the display. Page 12 Repeat steps 2 and 3 to set the hour. The hour is set and the minutes digits flash on the display.

Repeat steps 2 and 3 to set the minutes. The minutes settings is set. The unit automatically turns itself off after the minute setting has been set. Page Using The Unit 3. Make sure that the room is not too hot or cold. Within 1 hour after waking up is recommended. Measurements can be taken in light clothing. However, please remove thick clothes, such as sweaters, before taking a reading.

Insert the air plug into the air jack on the left side of the main unit. Page 17 Position the arm correctly. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff will be at the same level as your heart. Page 19 Check the measurement results. The unit automatically stores blood pressure and pulse rate into its memory. The buzzer will sound when measurement is completed. Irregular heartbeats can influence the results of the measurement.

The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated. If the measurement results are affected by irregular heartbeats but the result is valid, the result is shown together with the irregular heartbeat icon. Page 21 What is Arrhythmia? A heartbeat is stimulated by electrical signals that cause the heart to contract. Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio-electrical system that drives the heartbeat.

Typical symptoms are skipped heartbeats, premature contraction, an abnormally rapid tachycardia or slow bradycardia pulse. Every time you complete the measurement, the unit automatically stores the blood pressure and pulse rate. If there are three readings within 10 minutes of the last reading, the average of the three readings is displayed. The result from the most recent measurement is displayed.

The date and time of each measurement is displayed alternately with the measurement values. Important: If your systolic or diastolic pressure is outside the standard range, the heartbeat Page Quick Reference Guide 4. Quick Reference Guide If you are using this device for the first time, please read carefully chapter 3 of this instruction manual.

To help ensure a reliable reading, avoid eating, smoking, or exercising for at least 30 minutes before taking a measurement.

Note: Remove any tight-fitting clothing from your upper arm. Page Handling Errors And Problems 5. Movement during measurement Air plug disconnected. Arm cuff not applied correctly. Clothing is interfering with the arm cuff. Air is leaking from the arm cuff. The arm cuff was inflated above mmHg when inflating the cuff manually. Page 28 Error Display Device error. Note: The irregular heartbeat symbol may also be displayed with error messages.

Refer to Chapter 8. Page Troubleshooting Troubleshooting Problem The reading is extremely low or high. Arm cuff pressure does not rise. Arm cuff deflates too soon.

Cannot measure or readings are too low or too high. The unit loses power during measurement. Nothing happens when you press the buttons. Cause Apply the arm cuff Arm cuff not applied Page 30 5.

If the problem continues, try replacing the batteries Other problems. Page Maintenance And Storage 6. Page 33 Storage Keep the unit in its storage case when not in use.

Unplug the air tube from the air jack. Gently fold the air tube into the arm cuff. Note: Do not bend the air tube excessively. Place the arm cuff and main unit in the storage case. Page Optional Parts 7. This blood pressure monitor is designed according to the European Standard EN, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems. Some Useful Information about Blood Pressure 9. Blood pressure is a measure of the force of blood flowing against the walls of the arteries.

Arterial blood pressure is constantly changing during the course of the heart's cycle. The highest pressure in the cycle is called the Systolic Blood Pressure; This classification is based on the blood pressure values measured on people in a sitting position in outpatient departments of hospitals.

 


Omron intellisense manual



  WebInstructional Manual for all the Omron Healthcare products like blood pressure monitors, nebulizers, thermometers, weighing machine and pulse massager. Instructional Manual . Webthis instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit. Please . WebThe OMRON M3 Intellisense is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and .    