- Delta vfd el manual download pdf

Looking for:

- Products - Inverters - AC Motor Drives - Delta 













































     


Delta vfd el manual download pdf. Service Temporarily Unavailable



 

NPN mode without external power Factory setting B. NPN mode with external power Factory setting C. PNP mode without external power Factory setting D. Page 18 Use ground leads that comply with local regulations and keep them as short as possible. Refer to Appendix B for details. There may be an inrush current during power up. Page Main Circuit Use well-insulated motor, suitable for inverter operation.

Please connect an external optional brake unit BUE- series and brake resistor. Refer to BUE series user manual for details. Copper only, 75 3. Page Control Terminals 2. Output Frequency Pr. Page Operation Method 3. In most applications, the user can finish all parameter settings before start-up without the need for re-adjustment during operation.

The 11 groups are as follows: Group 0: User Parameters Group Last used frequency saved. Source of First Master Page Parameter Settings For Applications 4. The AC motor inertia loads motor drive will auto search motor speed and will accelerate when When used often, rotors resistor take motor cooling into consideration.

Page Description Of Parameter Settings 4. Page 55 Chapter 4 Parameters Page 56 Password has been set To set a password to protect your parameter settings. If the display shows 0, no password is set or password has been correctly entered in Pr. All parameters can then be changed, including Pr. The first time you can set a password directly. After successful setting of password the display will show 1.

Be sure to record the password for later use. Page 57 Chapter 4 Parameters 1. The mechanical characteristic curve of the motor will not be modified, but the mains frequency and mains voltage will be changed. This control mode allows the motor drive to do open loop running and also allow the motor drive to do closed loop running with a PG card an optional accessory. Page 60 Frequency Time Accel.

Time Time Time Resulting Resulting Decel. Time Resulting Accel. Time Page 61 Chapter 4 Parameters Linear acceleration, auto Deceleration. Page 62 Settings 0. That means the turbtable went back to the top after rounds. Example 02 Suppose that turntable is rotating at 1. Page 66 The motor stop method is usually determined by the characteristics of the motor load and how frequently it is stopped.

Page 67 Chapter 4 Parameters From the table, we see that the PWM carrier frequency has a significant influence on the electromagnetic noise, AC motor drive heat dissipation, and motor acoustic noise. The PWM carrier frequency will be decreased automatically by the ambient temperature and output current of the AC motor drives. The motor drive can start to run at power on or after reset.

Page 69 Chapter 4 Parameters The Line Start Lockout feature does not guarantee that the motor will never start under this condition. It is possible the motor may be set in motion by a malfunctioning switch. Page 70 Page 72 Group 3: Output Function Parameters Page 74 Frequency detection master range frequency detection range detection -2Hz range desired waiting time frequency DC braking time Page 76 Frequency Output Case 1: Pr.

Page 78 Example 4: Use of V potentiometer range via gain adjustment This example shows a potentiometer range of 0 to 5 Volts. Instead of adjusting gain as example below, you can set Pr. Gain adjustment Pr. Page 79 Chapter 4 Parameters Example 8: Use negative slope In this example, the use of negative slope is shown. Negative slopes are used in applications for control of pressure, temperature or flow. The sensor that is connected to the input generates a large signal 10V at high pressure or flow.

Page 80 Page 81 Chapter 4 Parameters AC motor drive will stop output and the motor free run if one of these Output Shutoff Stop settings is enabled. If the status of terminal is changed, AC motor drive will restart from 0Hz. Page 84 This parameter is to delay the signals on digital input terminals. The delay time is to debounce noisy signals that could cause the digital terminals to malfunction.

Page 86 Group 5: Multi-step speeds parameters Page 88 Group 6: Protection Parameters When this function is enabled, the AC motor drive will not decelerate further and keep the output frequency constant until the voltage drops below the preset value again.

Page 89 Chapter 4 Parameters Page 90 Page 93 Chapter 4 Parameters Refer to the rated rpm on the nameplate of the motor and use the following equation to determine the slip. Page 94 If temperature exceeds the setting level, motor will be coast to stop and is displayed. When the temperature decreases below the level of Pr. If the temperature decreases below the result Pr. Page 96 Group 8: Special Parameters It is recommended to start with a low DC Brake Current Level and then increase until proper holding torque has been achieved.

Output frequency Input B. Page 98 When the output current is less than the value of Pr. Page 99 Chapter 4 Parameters Page Page Chapter 4 Parameters 1.

Users can select the desired mode along with the serial port communication protocol in Pr. Page For RTU: 8.

Page Chapter 4 Parameters 3. Refer to chapter 5 for the GGnnH Parameters function of each parameter. X H Page 96 Group 4: Input Function Parameters The whole scale of the potentiometer can be used as desired. In addition to signals of 0 to 10V, the popular voltage signals also include signals of 0 to 5V, or any value under 10V. Page 98 Example 5: Use of negative bias in noisy environment In this example, a 1V negative bias is used.

In noisy environments it is advantageous to use negative bias to provide a noise margin 1V in this example. Page 99 Chapter 4 Parameters Example 8: Use negative slope In this example, the use of negative slope is shown.

Negative slopes are used in applications for control of pressure, temperature or flow. The sensor that is connected to the input generates a large signal 10V at high pressure or flow. Page Page Chapter 4 Parameters There are three different types of control modes: Page For Example: If Pr. You can activate internal terminals by Pr. Page Chapter 4 Parameters Weights Page Group 5: Multi-step speeds parameters Master frequency speed speed speed speed speed speed speed speed speed Page Group 6: Protection Parameters When this function is enabled, the AC motor drive will not decelerate further and keep the output frequency constant until the voltage drops below the preset value again.

During acceleration, the AC drive output current may increase abruptly and exceed the value specified by Pr. Page Over-Current Detection Level After removing the cause of the fault, use the reset command to reset the drive. Page Group 7: Motor Parameters Page Chapter 4 Parameters They can be cleared by setting to 0 and time is less than 1 minute is not recorded.

Page resistor-divider Refer to following calculation for protection level and warning level. Protection level Pr. Corresponding voltage level set in Pr. Page Chapter 4 Parameters resistor value Page Group 8: Special Parameters It is recommended to start with a low DC Brake Current Level and then increase until proper holding torque has been achieved.

Under such circumstances, DC Brake can be used to hold the load in position before setting it in motion. DC Brake during stopping is used to shorten the stopping time and also to hold a stopped load in position.

Page Output frequency Output voltage V Fig 1:B. Page Chapter 4 Parameters When momentary power loss is detected, the AC motor drive will block its output and then wait for a specified period of time determined by Pr. This parameter should be set at a value to ensure that any residual regeneration voltage from the motor on the output has disappeared before the drive is activated again. Page These parameters set the Skip Frequencies.

It will cause the AC motor drive never to remain within these frequency ranges with continuous frequency output. These six parameters should be set as follows Pr.

Therefore, when the AC motor drive is used without AVR function, the output voltage will be the same as the input voltage. By using this parameter, it will improve this situation greatly. The drift current zone of the high-power motors is usually in the low frequency area.

The RS master then controls each AC motor drive according to its communication address. Page Time-out Detection For example, 64 Hex. Communication Protocol 3. Page 1 03H: multi read, read data from registers. Example: writing data H to register H. AMD address is 01H. For example, reading 1 word from address H of the AC drive with address 01H. High byte of H is number of decimal places of H.

Illegal data address: The data address received in the command message is not available for the AC motor drive. Select input terminal accordingly.

Make sure this parameter setting does not conflict with the setting for Pr. Page When P is greater than 1, it will decrease the deviation and get the faster response speed. But if setting too large value in Pr.

NOTE The parameter can be set during operation for easy tuning. Page Chapter 4 Parameters This parameter defines an upper bound or limit for the integral gain I and therefore limits the Master Frequency. This parameter can limit the Maximum Output Frequency.

When frequency reaches wake up frequency, AC motor drive will accelerate from Pr. This parameter is used only for display and has no relation with Pr. Page Example: suppose that the set point of constant pressure control of a pump is 4kg, Pr. It means that deviation is 0. Page Chapter 4 Parameters Example: suppose that the set point of constant pressure control of a pump is 4kg, Pr.

Page Chapter 5 Troubleshooting 5. Page Ground Fault Chapter 5 Troubleshooting 5. Maybe AC motor drive has malfunction or misoperation due to noise. Reduce moment of inertia Need to check control method. Is output circuit cable or motor of AC motor drive grounded? Page Keypad Display Is Abnormal 5. AC motor drive works normally 5. It may cause malfunctioning of the control circuits and even damage the AC motor drive. Of course, there are solutions to increase the noise tolerance of an AC motor drive.

But this has its limits. Therefore, solving it from the outside as follows will be the best. Some solutions are: High Harmonics at Power Side High harmonics at power side during running can be improved by Once a fault is detected, the corresponding protective functions will be activated. Overload The AC motor drive detects excessive drive output current.

Page Reset 6. Disconnect AC power before processing! Only qualified personnel can install, wire and maintain AC motor drives. Please take off any metal objects, such as watches and rings, before operation. And only insulated tools are allowed. Page Keypad Check Items Is the display clear for reading? Any missing characters? Mechanical parts Check Items If there is any abnormal sound or vibration If there are any loose screws If any part is deformed or damaged If there is any color change by overheating If there is any dust or dirt Main circuit Page Chapter 6 Fault Code Information and Maintenance Terminals and wiring of main circuit Check Items If the wiring shows change of color change or deformation due to overheat If the insulation of wiring is damaged or the color has changed If there is any damage DC capacity of main circuit Check Items Page Transformer and reactor of main circuit Check Items If there is any abnormal vibration or peculiar smell Magnetic contactor and relay of main circuit Check Items If there are any loose screws If the contact works correctly Printed circuit board and connector of main circuit Check Items If there are any loose screws and connectors Page Chapter 6 Fault Code Information and Maintenance Cooling fan of cooling system Check Items If there is any abnormal sound or vibration If there is any loose screw If there is any change of color due to overheating Ventilation channel of cooling system Check Items If there is any obstruction in the heat sink, air intake or air outlet For V models, it is 1-phase models.

For 0. Refer to following specifications for details. Applicable Motor Output kW Max. Page Appendix B Accessories B. Please contact your nearest Delta representative for use of special resistors. The brake unit should be at least 10 cm away from AC motor drive to avoid possible interference. Please use the brake unit according to the Equivalent Resistor Value. If damage to the drive or other equipment is due to the fact that the brake resistors and the brake modules in use are not provided by Delta, the warranty will be void.

Together with the magnetic contactor MC in the mains supply circuit to the drive it offers protection in case of any malfunctioning. The purpose of installing the thermal overload relay is to protect the brake resistor against damage due to frequent brake or in case the brake unit is continuously on due to unusual high input voltage.

Page B. Weight g Correct wiring B Max. Page Application 2 Silicon rectifier and AC motor drive are connected to the same power. Correct wiring power Application 3 Used to improve the input power factor, to reduce harmonics and provide protection from AC line disturbances. The AC line reactor should be installed when the power supply capacity is kVA or more and exceeds 6 times the inverter capacity, or the Diagram A Please wind each wire 4 times around the core.

The actual value stored in the specified parameter. Communication port for connecting DeviceNet network 3. Address selector 4. Baud rate selector 5. Three LED status indicators for monitor. Refer to the figure below B. An 8 pins RJ cable, which is packed together with this communication module, is used to connect the RS port between VFD-EL and this communication module for power. This communication module will perform the function once it is connected.

Source Command Source B. Refer to chapter 1.

   